Wiring Diagram
Installation Manual
Street Smart Security
Wireless Emergency Line
Location of the control module is the most important determining factor for range and
reliability of your Wireless Emergency Line. Select a location that is as centrally
located as possible. Keep in mind that your customer will want to control the
operation of the garage door from the driveway, and will also expect the use of the
remote for alarm On/Off in the area of entry and exit.
Although you can wire at the panel, it may reduce labor and increase range by
installing the Wireless Emergency Line receiver at the point of entry or near a keypad.
Specifications
RECEIVER
• 12VDC Power Input
• Selectable: Form C Relay (N/O, N/C, Comm) 5amp
• Channel 1 - Keypad panic data output
(Programmable Medial/Panic)
Frequency 303Mhz
Stand by Power Consumption 15ma
Temperature Range -5°F to 160°F (Indoor use only)
1
Garage
Basement
Bedroom
Attic
2
Yellow Connect to yellow of keypad
*Moose panels connect to
white of keypad
Green Connect to green of keypad
Brown Relay Common
(5amp)
Brown/White Relay N/O
(5amp)
Blue/Green Relay N/C (5amp)
Red +12VDC
Black (-) Ground
3
4
Installation
Red Aux +
Black Aux -
Yellow Keypad Data Line
Green Keypad Data Line
5
Automatic Recognition Continued:
No. of Flashes Alarm Panel detected by the Wireless Emergency Line
1 No Alarm connected (WEL defaults to relay mode)
SEE PAGE 7 Default Mode
2 Napco 1000E Series (including 1008E, 1016E, etc.)
3 Moose Z880/Z900/Z950
4 Caddx 8600E, 8980E
5 Ademco Non Addressable
6 Ademco Addressable
7 DSC 1555/1565/5010 (Power 832)/5015/580
8 DSC 1550, 2525, 2550, 3000
9 Moose ZX200/ZX300/ZX400
10 Moose Z1100E, ADT A910
11
12 Moose Z1100
NOTE: If the WEL does not detect correctly,
call Technical Toll Free 888-768-2846 7am-5pm PST
* Please verify the panel is programmed for keypad PANIC or Medical, whichever is being used.
Point of Entry
Wiring and Auto Recognition
COMPLETE STEPS 1-5
Step 1)
Unplug the receiver from the wire harness.
Step 2) Wire the Red, Black, Yellow and Green to the keypad.
RED Connect to Keypad Red or Aux (+)
BLACK Connect to Keypad Black or Aux (-)
GREEN Connect to Keypad Green
YELLOW Connect to Keypad Yellow
*Moose ZX200/400/900/950 Connect to the White wire.
NOTE: You can make these connections at the panel or at the keypad
itself. If you place the Wireless Emergency Line in the garage or any
other location away from the panel you may choose to wire the
Wireless Emergency Line dir
ectly to the keypad.
Step 3) Make sure the alarm panel is powered up and operating.
Step 4) While watching the LED light on the Control module, plug the receiver into
the Wireless Emergency Line harness.
Step 5) The LED will blink 1 time on power up, after 2 seconds COUNT the flashes
that you see. The corresponding flashes will indicate which panel the
Wireless Emergency Line has detected.
Alarm Panel
+ -
Aux
Black
Red
123
456
789
Green Yellow
LED
Program
Button
Jumpers
Alarm
Keypad
Patent Pending - Part #WEL-Y
W
IRELESS
E
MERGENCY
L
INE
Now with
Automatic Alarm
Recognition
Recommended
placement for
Wireless
Emergency Line
WEL
Press and release for relay mode, press
and hold for 3 seconds for PANIC
output. Relay can be wired to any zone
for an additional panic output.
REMOTE CONTROL
Battery
(2)
CR1616Lithium
Range 75-100 feet
Options
Optional 2 button remote for both
Medical and Police on one remote.
Part # CEREM2
The WEL on the following panels self enrolls as a specific keypad address code.
Ademco addressable Address #3
Moose ZX200/ZX400 addressable Address #4
DO NOT USE ANY OF THESE ADDRESS CODES IF YOU ARE USING ONE OF THE
ABOVE PANELS. EXAMPLE: If you are using an Ademco Addressable, no keypads
can use address #3 since the WEL will automatically enroll itself as address #3.
Programming the WEL
To change from Panic to Medical or to change from Delay to Instant activation locate
the two jumpers next to the wire harness.
Jumper closest to the harness IN (Default) Panic
Jumper closest to the harness removed Medical
Jumper farthest from the harness IN (Default) Delay Activation
Jumper farthest from the harness removed Instant Activation