This data block is used to assign the programmable outputs. The control is equipped with one programmable on-board
output (PGO1) and one bell output (BELL). Additional outputs can be obtained in groups of ten by the addition of output
driver modules (ZXODM) or a zone expander (ZXEXP). The 10 outputs on ODM2 are identical to the 10 outputs on the
zone expander.
Each output is assigned a condition (i.e.: Burglar, Fire, Status, Alarm) and areas to which it should respond when the
condition is active in those areas. For access conditions, the output is assigned to a control station(s). Output conditions 1
- 8 ignore the area setting.
3.2.5 Output Definitions Description
The Installer passcode has the authority level to perform the following operations:
•Access from Keypad Initiate Call to RPM/2 Pro
•Arm (AWAY, STAY, NIGHT) Remote Connect
•Disarm if Armed by an Installer Reset Smoke Power
•Change Arming Level Program RF Data
•Default User Code 1 RF Signal Strength
•Edit Zone Names Set Clock
•Force-Arm Silence Trouble
•View & Print Event Log View Alarm Memory
•Bypass Zones Battery Test
•Chime Enable/Disable Bell Test
•Default Function Map Comm Test
•Edit Function Map (except Zone Names & User Codes) Keypad Test
•Silence/Cancel Alarm if not Armed or if Armed by Installer Walk Test
Silence Bell without Disarm if Armed by other than Installer Adjust Days Until Next Auto Comm Test
• Disabled if Lockout Local Programming is enabled (See table in Section 3.2.14.)
Output Definitions Default Table
Condition Area or Keypad Condition Area or Keypad
Loc Default Loc Default Loc Default Loc Default
Control - Bell Zone Expander or ODM 2
Output 00 [267] 1 Output 01 [290] 9 [291] 1
Control Output 02 [292] 1 [293] 1
Output 01 [268] 13 [269] 1 Output 03 [294] 10 [295] 1
ODM 1 Output 04 [296] 11 [297] 1
Output 01 [270] 9 [271] 1 Output 05 [298] 15 [299] 1
Output 02 [272] 1 [273] 1 Output 06 [300] 26 [301] 1
Output 03 [274] 10 [275] 1 Output 07 [302] 14 [303] 1
Output 04 [276] 11 [277] 1 Output 08 [304] 21 [305] 1
Output 05 [278] 15 [279] 1 Output 09 [306] 29 [307] 1
Output 06 [280] 26 [281] 1 Output 10 [308] 34 [309] 1
Output 07 [282] 14 [283] 1
Output 08 [284] 21 [285] 1
Output 09 [286] 29 [287] 1 * Output conditions 34 and 35 add combinations of keypads 1 - 6.
Output 10 [288] 34 [289] 1 Conditions 9 - 33 are specified as a combination of Areas 1 & 2.