If the Output Condition is “Ready”, “Armed AWAY”, “Armed STAY”, “Armed NIGHT”, “Armed & Exit Time Expired”,
“Exit Time”, “Entry Time”, “Annunciation”, “Key 4 Output”, “Key 5 Output”, or “Key 6 Output”, then the Areas of
Operation should be limited to a single area.
Output Condition See Section 3.2.5.2 for complete descriptions
0 = Not Used 19 = Exit Time
1 = Fire Alarm 20 = Entry Time
2 = Fire Supervisory 21 = Pre-Alarm Warning Time
3 = Duress 22 = Annunciation
4 = Low Battery 23 = Auto-Arm Warning
5 = Failed to Comm 24 = Closing Ringback
6 = Telco Line Fault 25 = Trouble
7 = Telco Line Seized 26 = Chime
8 = Ground Start 27 = Universal
9 = Burglar Alarm 28 = Listen-In Module Output
10 = Hold-up Alarm 29 = Lamp Trigger
11 = Auxiliary Alarm 30 = Key 4 Output
12 = Bell Output Trigger 31 = Key 5 Output
13 = Violation 32 = Key 6 Output
14 = Ready 33 = RF Annunciator
15 = Armed AWAY 34 = Access by Keypad
16 = Armed STAY 35= Quick Access by Keypad
17 = Armed NIGHT 101 - 130 = Zone (1 to 30) Violated
18 = Armed and Exit Time Expired 201 - 230 = Zone (1 to 30) In Alarm or Senior Watch
Areas of Operation (for Output Conditions 9 - 33) [add up selections]
1 = Area 1 (for Output Conditions 34 & 35)
2 = Area 2 1 = Control Station 1
3 = Both 2 = Control Station 2
4 = Control Station 3
8 = Control Station 4
16 = Control Station 5
32 = Control Station 6
Item Valid Range
The following table refers to programming locations 267 through 309.
The Bell Output is assignable to a combination of areas and may activate due to an alarm condition in any of the areas. A
Fire Alarm from a Fire or Verified Fire zone or the ‘A Key will always activate the Bell Output. A Burglar Alarm, a Burglar
Tamper, a Holdup Alarm, the ‘B’ Key, an Auxiliary Alarm, or the ‘C’ Key may activate the Bell Output.
Each alarm type is programmable for its Bell Output operation. (See Section 3.2.6.) If more than one alarm type is active
at the same time, the Bell Output will annunciate the highest priority alarm. The priority order is Fire, Auxiliary, Burglar,
and Holdup.
If any of the Bell Output’s areas have Closing Ringback Annunciation set to “Ringback Output, Keypads, and Bell Output”,
the Bell Output will emit a two (2) second ringback tone. (See Section 3.2.1.)