Note 1: Restarting Exit Time
If an exit time is counting down from an AWAY arming, the exit time may be automatically restarted once to reduce false alarms.
The exit time will be restarted if a Perimeter (arm in STAY mode and arm in NIGHT mode) Burglar zone is violated anytime during the last
ten seconds of exit time.
If the exit time is not due to an Exit Arm or a Scheduled Arming, then the exit time will be restarted if it expires and a Perimeter (Arm in STAY
mode and Arm in NIGHT mode) Burglar zone has not been violated during the exit time (i.e.: nobody went out the door).
Note 2: Entry Time versus Pre-Alarm Warning Time
Assuming Exit, Entry and Pre-Alarm Warning Times are inactive, a violation of an armed Burglar zone will cause the following actions
depending on the area’s arm level and the type of Burglar zone:
3.3 Programming Notes
Note 3: Exit Arm
An Exit Arm is intended to automatically arm an area ten minutes after the premises are vacated. An Exit Arm will only be attempted when
it is enabled for an area and the area is disarmed and not in alarm. The end user can disable the Exit Arm feature on a day-to-day basis (see the
appropriate User Guide). If a Disable Exit Arming is performed, the Exit Arm will be disabled until midnight.
When a Delay Burglar zone restores from a violation, the area’s Exit Arm timer is started at ten minutes. During this time, the Control Station
may display a visual indication of the impending action and the amount of time remaining. An audible warning signal will occur at two
minutes until arming and at one minute until arming. When any Burglar zone is violated, the area’s Exit Arm timer is halted. If a Delay zone
restores from a violation while the timer is running, the timer is restarted at ten minutes. If an Instant or Follower Burglar zone restores from
a violation, the timer is halted.
If the timer expires (i.e.: ten minutes of no Burglar zone activity following a Delay zone restoration), then the system attempts to arm the area
in the AWAY mode. If Force-Arming is enabled, then a Force-Arm may occur if needed. If the arming is successful, then Exit time is started
and an Auto-Arm event is logged to be reported. If the arming cannot be completed, then nothing will happen.
Note 4: Force-Arming
If Force-Arming is enabled for an area, then an arming from a keyswitch zone, an Exit Arming or a Scheduled Arming will be Force-Armed
if necessary.
Note 5: LED Control Stations
The Secondary Area setting is ignored for LED Control Stations since they cannot provide area information and prompts. Therefore, LED
Control Stations cannot have a Secondary Area.
AWAY STAY STAY INSTANT NIGHT NIGHT INSTANT
Instant Burglar Instant Alarm Pre-Alarm Warning Pre-Alarm Warning Pre-Alarm Warning Pre-Alarm Warning
Time Time Time Time
Delay Burglar Entry Time Entry Time Instant Alarm Entry Time Instant Alarm
Follower Burglar Pre-Alarm Warning Pre-Alarm Warning Pre-Alarm Warning Pre-Alarm Warning Pre-Alarm Warning
Time Time Time Time Time
WWW.DIYALARMFORUM.COM